Product Details:
|
Product Name: | Water Cooled Screw Chiller | Cooling Capacity: | 100-2000KW |
---|---|---|---|
Cooling Temperature: | 5℃-35℃ | Compressor Type: | Screw Compressor |
Control System: | Siemens PLC/Microprocessor Control | Evaporator: | Shell And Tube/Falling Film/Flooded |
Condenser: | Shell And Tube | Noise Level: | ≤60dB(A) |
Protection: | Compressor Overload, High/Low Pressure, Water Flow, Phase Sequence, Anti-freezing | Refrigerant: | R22/R407C/R134A/R410A |
Voltage: | 380V/3N/50Hz | ||
Highlight: | R134A Portable Water Cooled Chiller,R134A Portable Water Chiller,R410A Portable Water Cooled Chiller |
Hot and Cold Dual-circuit Temperature Control Chiller
A hot and cold constant temperature chiller, also known as a heat pump chiller or hot water chiller, is a device that integrates cooling and heating functions, and achieves the dual functions of cooling and heating through heat pump technology.
Product Features:
The advantages of hot and cold constant temperature chillers include:
1.Double circulation system: Two-system integrated chiller has a double circulation system, which can provide cooling water for two different cooling systems at the same time, which improves the utilization rate of the equipment.
2.High efficiency and energy saving: The two-system integrated chiller adopts high-efficiency refrigeration technology and cooling water pump, which can realize energy saving and environmental protection, reduce energy consumption, and improve the energy efficiency ratio of the equipment.
3.Stable and reliable: The two-system integrated chiller has an independent refrigeration system and cooling system, which can ensure the stability and reliability of the equipment during operation.
4.High space utilization: The two-system integrated chiller has a compact design and takes up little space, which can meet the occasions with limited space.
5.Easy to operate: The two-system integrated chiller is easy to operate and easy to maintain, which can reduce maintenance costs and difficulty.
In short, the two-system integrated chiller is a chiller with a double circulation system, which can provide cooling water for two different cooling systems at the same time. It has the advantages of high efficiency, energy saving, stability and reliability, high space utilization, and easy operation. It is suitable for Occasions that need to provide cooling water for two different cooling systems at the same time, such as central air conditioning systems, cooling tower systems, industrial refrigeration systems, etc.
① Compressor | ⑤ Evaporator | ⑨ Temperature sensor | ⑬ Bypass valve |
② Condenser | ⑥ Ball valve | ⑩ Water tank | ⑭ Low voltage controller |
③ Filter drier | ⑦ Antifreeze switch | ⑪ Water pump pressure gauge | ⑮ High voltage controller |
④ Expansion valve | ⑧ Float switch | ⑫ Water pump | ⑯ Pressure relief valve |
Techinical Parameters:
Model | RX-1HP | RX-2HP | RX-3HP |
RX-4HP |
RX-5HP | RX-6HP | RX-8HP | RX-10HP | ||
Cooling capacity | KW/h | 3.1 | 6.2 | 9.3 | 12.4 | 15.5 | 18.6 | 24.8 | 31 | |
Kcal/h | 2,700 | 5,400 | 8,100 | 10,800 | 13,500 | 16,200 | 21,600 | 27,000 | ||
Temperature range | 5℃-35℃(Below 0℃ can be customized) | |||||||||
Power supply | 1PH-220V 50HZ/60HZ 3PH-380V/415V 50HZ/60HZ | |||||||||
Total power | KW | 1.21 | 2.03 | 2.84 | 3.7 | 4.5 | 5.7 | 7.33 | 8.83 | |
Compressor | Type | Hermetic scroll type or piston | ||||||||
Power | KW | 0.75 | 1.50 | 2.25 | 3.00 | 3.75 | 4.50 | 6.00 | 7.50 | |
Circulating pump | Power | KW | 0.375 | 0.375 | 0.375 | 0.375 | 0.75 | 0.75 | 0.75 | 1.5 |
Head | m | 22 | 22 | 22 | 22 | 23 | 23 | 23 | 21.5 | |
Refrigerant | Type | R22/R407c/R134a/R410a | ||||||||
Control method | Temperature Sensing External Pressure Equalizing Expansion Valve | |||||||||
filling volume | Kg | 0.50 | 1.00 | 1.50 | 2.00 | 2.50 | 3.00 | 4.00 | 5.00 | |
Evaporator | Flow | m³/h | 0.82 | 0.98 | 1.45 | 1.88 | 2.42 | 2.92 | 3.75 | 4.85 |
water capacity | m³ | 0.028 | 0.04 | 0.05 | 0.05 | 0.065 | 0.065 | 0.13 | 0.18 | |
Diameter | inch | 1/2" | 3/4" | 1" | 1-1/2" | 1-1/2" | ||||
Condensator | Type | Efficient brass sets corrugated aluminum fin | ||||||||
Fan | Type | Axial flow | ||||||||
air volume | m³/h | 1000 | 2000 | 3000 | 4000 | 5000 | 6000 | 8000 | 10000 | |
Protective device | High and low pressure switch, antifreeze protection, fusible plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc. | |||||||||
Machine size | L | mm | 680 | 800 | 1040 | 1140 | 1140 | 1200 | 1400 | 1400 |
W | mm | 420 | 480 | 555 | 620 | 620 | 650 | 725 | 725 | |
H | mm | 720 | 850 | 1060 | 1200 | 1200 | 1160 | 1450 | 1450 | |
Unit weight | Kg | 60 | 90 | 130 | 140 | 170 | 210 | 270 | 350 |
Model | RX-12HP | RX-15HP | RX-20HP | RX-25HP | RX-30HP | RX-40HP | RX-50HP | RX-60HP | ||
Cooling capacity | KW/h | 37.2 | 46.5 | 65 | 77.5 | 93 | 124 | 155 | 186 | |
Kcal/h | 29,059 | 37,965 | 50,805 | 61,683 | 74,992 | 97,675 | 116,521 | 156,249 | ||
Temperature range | 5℃-35℃(Below 0℃ can be customized) | |||||||||
Power supply | 1N-220V 50HZ/60HZ 3N-380V/415V 50HZ/60HZ | |||||||||
Total power | KW | 11.4 | 13.62 | 19.8 | 22.75 | 28.3 | 39.2 | 46.75 | 56.1 | |
Compressor | Type | Hermetic scroll type or piston | ||||||||
Power | KW | 9 | 11.25 | 15 | 18.75 | 22.5 | 30 | 37.5 | 45 | |
Circulating pump | Power | KW | 1.5 | 1.5 | 2.2 | 2.2 | 4 | 4 | 4 | 5.5 |
Head | m | 21.5 | 21.5 | 22 | 22 | 25 | 25 | 25 | 26 | |
Refrigerant | Type | R22/R407c/R134a/R410a | ||||||||
Control method | Temperature Sensing External Pressure Equalizing Expansion Valve | |||||||||
filling volume | Kg | 7.2 | 9.1 | 12.2 | 15.3 | 18.6 | 24.5 | 30.6 | 36.8 | |
Evaporator | Flow | m³/h | 5.81 | 7.6 | 10.16 | 12.34 | 15.2 | 19.53 | 23.3 | 30.52 |
water capacity | m³/h | 0.18 | 0.21 | 0.28 | 0.32 | 0.32 | 0.61 | 0.66 | 0.72 | |
Diameter | inch | 1.5" | 2" | 2.5" | 3" | |||||
Condensator | Type | Efficient brass sets corrugated aluminum fin | ||||||||
Fan | Type | Axial flow | ||||||||
air volume | m³/h | 12000 | 15000 | 20000 | 25000 | 30000 | 40000 | 50000 | 60000 | |
Protective device | High and low pressure switch, antifreeze protection, fusible plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc. | |||||||||
Machine size | L | mm | 1400 | 1750 | 2000 | 2000 | 2200 | 2000 | 2000 | 2400 |
W | mm | 725 | 750 | 900 | 900 | 900 | 1800 | 1800 | 1800 | |
H | mm | 1450 | 1500 | 1770 | 1770 | 1770 | 2200 | 2300 | 2300 | |
Unit weight | Kg | 370 | 480 | 590 | 590 | 880 | 1000 | 1280 | 1420 |
Application Industry:
The cold and hot integrated constant temperature chiller is widely used in occasions that need to provide cooling and heating at the same time and maintain a constant temperature, such as:
1. Industrial production: used for cooling and heating that require constant temperature in industrial processes, such as chemical reaction, injection molding, electronic manufacturing, etc.
2. Laboratory and scientific research: It is suitable for experimental equipment, reactors, constant temperature baths, etc. in laboratories and scientific research institutions, providing constant temperature cooling and heating.
3. Medical field: In medical equipment, such as medical cold therapy equipment, laboratory equipment, medical imaging equipment, etc., it is necessary to have cooling and heating functions at the same time, and to maintain a constant temperature.
4. Other applications: The integrated cooling and heating constant temperature chiller can also be used in environments with high temperature control requirements, such as temperature simulation testing, semiconductor manufacturing, etc.
The advantage of the integrated cooling and heating constant temperature chiller is that it integrates cooling, heating and constant temperature control functions, which can meet the needs of various application scenarios, provide stable temperature control and efficient energy utilization.
Automotive Manufacturing Chemical Engineering Electronics Industry Electroplating Industry
Injection Molding Industry Pharmaceutical Industry Plastic Packaging Industry Printing Industry
Upport and Services:
Hot and cold constant-temperature chiller technical support and service includes:
1. 24/7 customer support
2. Remote guidance installation and maintenance
3. Remote Diagnostics and Troubleshooting
4. Phone/Email Advice and Guidance
5. User friendly documentation and manuals
6. Software Updates and Upgrades
7. Cost price of spare parts and consumables
Packing and Shipping:
water cooled screw chillers are packaged and shipped in standard plywood wooden boxes. All components are secured and protected with a film, and the unit is then placed on a pallet for easy transport. And affix the shipping mark information label on the wooden box to ensure correct delivery.
How does the thermostatic control system of a hot and cold thermostatic chiller work?
The thermostatic control system of a hot and cold integrated thermostatic chiller is a key component for monitoring and adjusting water temperature to achieve constant temperature. The working principle of a general thermostatic control system is as follows:
1. Temperature sensor: The thermostatic control system usually contains one or more temperature sensors for real-time monitoring of water temperature. These sensors can be devices based on principles such as thermistors, thermocouples, or semiconductors. They convert water temperature into electrical signals and transmit them to the control system.
2. Controller: The controller in the thermostatic control system is an intelligent electronic device that receives signals from temperature sensors and controls the operation of heating elements according to the set target temperature and control strategy. The controller usually contains a microprocessor and related circuits for processing input signals, executing control algorithms, and outputting control signals.
3. Feedback loop: The controller implements closed-loop control of temperature through a feedback loop. It compares the actual measured water temperature with the set target temperature and adjusts the power of the heating element based on the comparison result. If the actual temperature is lower than the target temperature, the controller will increase the heating power; if the actual temperature is higher than the target temperature, the controller will reduce the heating power.
4. Heating element control: The thermostatic control system achieves temperature regulation by controlling the operation of the heating element. The heating element can be an electric heater, a heat exchanger, or other suitable heating device. The controller provides electrical energy or other forms of energy to the heating element as needed to increase the water temperature.
5. Safety protection: The thermostatic control system usually also includes safety protection functions to ensure the safe operation of the system. These protection functions include over-temperature protection, over-current protection, short-circuit protection, etc. to prevent over-temperature, over-current or other fault conditions.
By continuously monitoring the actual water temperature and adjusting the operation of the heating element, the thermostatic control system can keep the water temperature stably within the set target temperature range. In this way, the integrated hot and cold constant temperature chiller can provide constant cooling or heating effects according to demand, and is suitable for occasions where precise temperature control is required.