Product Details:
|
Product Name: | Chemical Chiller | Cooling Capacity: | 10-500KW |
---|---|---|---|
Max Ambient Temperature: | 45℃ | Compressor Type: | Screw Compressor |
Control System: | PLC/ | Evaporator: | Shell And Tube/Falling Film/Flooded |
Max Working Pressure: | 4.2MPa | Noise Level: | ≤75dB(A) |
Refrigerant: | R22/R407C/R134A/R410A | Voltage: | 50HZ/60HZ |
Highlight: | 60HZ Recirculating Water Chiller System,60HZ Modular Air Cooled Chiller,Industrial Modular Air Cooled Chiller |
Low Carbon Technology Of Chemical Chillers Reshapes The Industrial Cooling Ecosystem
Chemical chillers are refrigeration equipment designed specifically for complex working conditions in the chemical industry. They can provide stable and accurate low-temperature cooling media for various reactors, condensers, heat exchangers and other equipment in the chemical production process. By controlling the process temperature, they ensure that chemical reactions are carried out under safe and efficient conditions, avoiding product quality degradation, equipment damage and even safety accidents due to abnormal temperature.
Product Features:
Chemical chillerhave the following characteristics:
1.High efficiency and energy saving: The industrial air cooler adopts high-efficiency and energy-saving compressors and coolers, which have high cooling efficiency and can save energy.
2.Flexible installation: The industrial air cooler can be installed indoors or outdoors, and the type selection and installation can be carried out according to specific needs.
3.Simple maintenance: The maintenance of industrial air coolers is relatively simple, and only requires regular cleaning and maintenance, which is relatively easy to maintain.
4.Long service life: The main components of the industrial air cooler have a long service life, which can ensure the stable operation of the equipment.
5.High temperature control accuracy: TheChemical chiller is equipped with a precise temperature control system, which can achieve precise temperature control.
Techinical Parameters:
Model | RX-3HP | RX-5HP | RX-8HP | RX-10HP | JLSLF-12HP | RX-15HP | RX-20HP | RX-25HP | RX-30HP | RX-40HP | ||
Cooling capacity | KW/h | 8.85 | 14.75 | 23.6 | 29.5 | 35.4 | 44.25 | 59 | 73.75 | 88.5 | 118 | |
Kcal/h | 24,338 | 40,563 | 64,900 | 81,125 | 97,350 | 121,688 | 162,250 | 202,813 | 243,375 | 324,500 | ||
Temperature range | 3℃~35℃ | |||||||||||
Power supply | 1N-220V 50HZ/60HZ 3N-380V/415V 50HZ/60HZ | |||||||||||
Total power | KW | 2.57 | 4.31 | 7.65 | 9.9 | 11.4 | 13.7 | 18.8 | 22.59 | 27.1 | 36.1 | |
Compressor | Type | Hermetic scroll type or piston | ||||||||||
Power | KW | 2.25 | 3.75 | 6 | 7.5 | 9 | 11.25 | 15 | 18.75 | 22.5 | 30 | |
Refrigerant | Type | R22/R407c/R134a/R410a | ||||||||||
Control method | Temperature Sensing External Pressure Equalizing Expansion Valve | |||||||||||
volume | Kg | 1.8 | 3 | 4.8 | 6 | 7.2 | 9 | 12 | 15 | 18 | 24 | |
Cooling wind | m³/h | 370 | 800 | 1560 | 2300 | 2750 | 3360 | 4100 | 4800 | 5400 | 6200 | |
Cold wind pressure | Pa | 340 | 520 | 780 | 890 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | |
Fan power | KW | 0.35 | 0.5 | 0.75 | 1.5 | 1.8 | 2.2 | 3 | 3.75 | 4.5 | 6 | |
Cooling air volume | m³/h | 3000 | 5000 | 8000 | 10000 | 12000 | 15000 | 20000 | 25000 | 30000 | 40000 | |
Blower power | KW | 0.28 | 0.36 | 0.6 | 0.75 | 0.9 | 1.2 | 1.2 | 1.6 | 2.4 | 3.6 | |
Outlet pipe diameter | mm | 100 | 125 | 150 | 150 | 150 | 150 | 200 | 200 | 250 | 300 | |
Machine size | L | mm | 800 | 1100 | 1330 | 1330 | 1330 | 1550 | 1760 | 1970 | 2000 | 2100 |
W | mm | 600 | 700 | 750 | 750 | 750 | 780 | 860 | 900 | 1130 | 1400 | |
H | mm | 1190 | 1240 | 1330 | 1330 | 1330 | 1460 | 1560 | 1700 | 1660 | 1750 | |
Unit weight | Kg | 150 | 260 | 360 | 420 | 460 | 530 | 600 | 700 | 820 | 950 |
Application Industry:
Chemical chiller are used in the following industries and occasions:
1. Chemical synthesis reaction: In chemical synthesis, many reactions are sensitive to temperature. For example, in organic synthesis reactions, the chiller absorbs the reaction heat through circulating cooling water, controls the temperature fluctuation in the reactor within a very small range, ensures that the reaction is carried out at an appropriate temperature, and improves the reaction selectivity and yield. For exothermic reactions such as polymerization reactions, precise temperature control can avoid overheating of the reaction, resulting in product deterioration, equipment damage, and even safety accidents.
2. Material cooling and crystallization: During the crystallization process of chemical products, the chiller provides a stable low-temperature environment, allowing the material to gradually crystallize at a suitable temperature, which helps to obtain products with uniform particles and high purity. For products such as fine chemical intermediates that require rapid cooling and crystallization, the chiller can meet their rapid cooling requirements and shorten the production cycle.
3. Storage and transportation: Some chemical raw materials and products need to be stored and transported in a low-temperature environment to prevent deterioration, volatilization, or dangerous reactions. The chiller can provide precise low-temperature cooling for storage tanks and transport containers to ensure material quality and safety.
Automotive Manufacturing Chemical Engineering Electronics Industry Electroplating Industry
Injection Molding Industry Pharmaceutical Industry Plastic Packaging Industry Printing Industry
Upport and Services:
Chemical chiller technical support and service includes:
1. 24/7 customer support
2. Remote guidance installation and maintenance
3. Remote Diagnostics and Troubleshooting
4. Phone/Email Advice and Guidance
5. User friendly documentation and manuals
6. Software Updates and Upgrades
7. Cost price of spare parts and consumablesPacking and Shipping:
How does the chemical chiller control system work?
1. Temperature monitoring: Install a temperature sensor on the outlet pipe of the chiller or the equipment that needs to be cooled, and its function is to monitor the water temperature in real time.
2. Feedback and adjustment: The temperature sensor transmits the monitored water temperature signal to the controller, and the controller compares the actual water temperature with the set constant temperature value. When the actual water temperature is higher than the set value, the controller will increase the cooling capacity of the refrigeration system, such as increasing the speed of the compressor to allow more refrigerant to participate in the circulation and enhance the cooling effect, or increase the opening of the throttle valve to allow more refrigerant to flow into the evaporator to absorb heat; if the actual water temperature is lower than the set value, the controller will reduce the cooling capacity, such as reducing the compressor speed or reducing the throttle valve opening, so as to ensure that the water temperature always remains within the set constant temperature range.
4. Protection function: The control system also has a variety of protection functions. For example, the pressure of the refrigeration system is monitored by the pressure protection device. When the pressure is too high or too low, it will automatically shut down and sound an alarm to prevent the equipment from being damaged due to abnormal pressure. Overload protection is set. When the compressor, water pump and other equipment are overloaded, the power supply is automatically cut off to avoid equipment burning. There is also liquid level protection to monitor the liquid level of refrigerant or cooling water. When the liquid level is too low, an alarm will be sounded and the machine will shut down to prevent the refrigeration effect from being affected or the equipment from being damaged due to insufficient liquid level.
Contact Person: Mr. Toms li
Tel: 17388732852
Fax: 86-0769-86666173